Added to cart successfully !

Annexin V-APC / 7-AAD Apoptosis Detection Kit[218]

Size:  
Qty:
- +
Price:   $75
Cat Number:  E-CK-A218
Lead Time:   7~10 days

Applications:  Apoptosis

Add to cart

Introduction

Elabscience® Annexin V-APC/7-AAD Cell Apoptosis Detection kit is developed to identify apoptotic and necrotic cells.

Annexin V is a member of the annexin family, which binds to phosphatidylserine (PS) in a calcium-dependent manner. Annexin V-APC, the APC-conjugated format, binds specifically to the PS on the outer leaflet of apoptotic cell membrane and can be detected with flow cytometry or fluorescence microscopy.

7-AAD (7-amino-actinomycin D) has a high DNA binding constant and is efficiently excluded by intact cells. It is useful for DNA analysis and dead cell discrimination during flow cytometric analysis. Due to the loss of integrity of membrane, 7-AAD can enter late apoptotic or necrotic cells to stain DNA. Cells at different apoptotic stages can be distinguished by using Annexin V and 7-AAD.



Components


Cat.

Products

20 Tests

50 Tests

100 Tests

200 Tests

Storage

E-CK-A117

Annexin V-APC Reagent

100 μL

250 μL

500 μL

1 mL

2~8°C

E-CK-A151

Annexin V Binding Buffer (10 ×)

1.4 mL×2

5.5 mL

11 mL

11 mL×2

2~8°C

E-CK-A162

7-AAD Viability Staining Solution

100 μL

250 μL

500 μL

1 mL

-20°C

Manual

 One Copy






Jurkat cells were treated with 5 μM Camptothecin and detected with this kit.



Jurkat cells were cultured with (Right) or without (Left) 5 μM Camptothecin for 4 h. Annexin V-APC single-positive cells were early apoptotic cells, Annexin V-APC and 7-AAD double-positive cells were necrotic or late apoptotic cells, and 7-AAD single-positive cells were naked nuclei.



Instructions

The Annexin V Binding Buffer (10 ×)[E-CK-A151] is a 10 × concentrated solution. Dilute with DI water to 1 × working solution before use.

For example: Take 1 mL Annexin V Binding Buffer (10 ×), dilute with DI water to 10 mL.



Storage

Annexin V-APC and 7-AAD Viability Staining Solution should be stored in dark.

7-AAD Viability Staining Solution should be split into small tubes and stored at -20°C.

Other reagents should be stored at 2~8°C.



Cautions

1.For maximal assay performance, this kit should be used within 12 months. Avoid freeze / thaw cycles.

2. For FCM analysis, please set untreated cells stained with both Annexin V-APC and 7-AAD as negative control. As for compensation controls, please use drug-treated cells stained with either Annexin V-APC or 7-AAD.

3. Annexin V-APC can be detected in APC channel while 7-AAD can be detected in PerCP/Cy5.5 channel.

4. Detect apoptosis as soon as possible after staining to avoid the increase number of apoptosis or necrosis.

5. Avoid extended exposure of the samples to direct light to protect the fluorophores from quenching.

6. For your safety and health, please wear the lab coat and disposable gloves before the experiments.

If you have any question about the product, please feel free to contact us or leave a message